Skip to main content

Detector operation status

The current detector status is displayed on the interactive map on the main page of the web interface in the form of a detector marker of a certain color.

The marker color changes depending on the detector status.

Detectors operation status

Description of detector statuses and conditions of their determination in the System

In the table below are described the detector statuses and conditions of their determination in the SmartRoad System

Marker colorDescriptionDetector status
GreenThe detector works correctly, data flows from the detector to the adapter and then to the System- The detector participates in the adapter polling (ACTIVE)
- The extended mode (EXTENDED_MODE) is activated on the detector. This mode is activated only in “0C” type detectors. It is used to detect lanes and classes of tracked objects (OBJECTS)
- The System receives data from the detector (data is being read - READING).
BlueThe detector is in maintenance or in the setup modeThe detector is undergoing maintenance (in the setup mode). The detector data is redirected to an IP address that is different from the IP address of the server where the adapter is located.
RedThe adapter does not transmit data to the System (to the user)Determined by the System with the fulfillment of one of the following conditions:
- “Bootloader_mode” mode is activated in the detector the;
- Error when connecting the adapter to the detector (CONNECTION_ERROR);
- The adapter is connecting to the detector (the adapter attempts to connect to the detector - CONNECTING);
- The adapter successfully connected to the detector - CONNECTED, while the data has not yet been transmitted to the user (to the System)
- No data from the adapter for more than two minutes (DEAD_ADAPTER).
- Standby mode (TIMEOUT).
YellowWarning about a possible problem with the detectorDetermined by the system with the fulfillment of one of the following conditions:
- The system does not receive PVR data from the detector within 10 minutes (NO PVR);
- Status data is not recorded in the database (NO DATA)
- Blinding, the detector is blinded due to the snow, ice or another obstacle blocking the detector antenna signal (BLIND);
- Interference – obstacle is detected on the frequency detector channel, affecting object detection (as a rule, interference occurs due to the another detector signal located or installed nearby - INTERFERENCE);
- Rain – the presence of precipitation (rain) has been detected, which can affect the efficiency of object detection (RAIN);
- Hardware error – an error has been identified in the detector hardware, which may negatively affect the correct operation of the detector (HARDWARE_ERROR).
- In this case, the detector can transmit PVR data, but if at least one of the conditions above is detected, for example Interference, the System will still determine the detector status as Yellow (INTERFERENCE).
GreyThe detector has been removed from a project or moved to another project (displayed as dark gray on the map and light gray on the status chart)The detector is removed from the project or moved to another project, and the user can receive statistical data from the detector over past time intervals.